Momik automates lighting design in Revit. Fully I.S. EN 12464-1 compliant. Weeks of work in minutes.
What takes weeks manually, Momik does in minutes. Fully automated lighting layout in Revit.
Every design meets I.S. EN 12464-1 requirements automatically. No manual norm-checking needed.
Works directly inside Autodesk Revit. No exports, no external tools, no workflow disruption.
AI-powered clash detection ensures every fixture placement is structurally valid from the start.
Reference lux levels, uniformity ratios, UGR limits, and colour rendering requirements per room type under I.S. EN 12464-1.
| Room / Task Type | Illuminance (Em) | Uniformity (Uo) | Glare (UGR) | Colour (Ra) |
|---|---|---|---|---|
| Open-plan office | 500 lx | ≥ 0.60 | ≤ 19 | ≥ 80 |
| Meeting / conference room | 500 lx | ≥ 0.60 | ≤ 19 | ≥ 80 |
| Reception / lobby | 300 lx | ≥ 0.40 | ≤ 22 | ≥ 80 |
| Corridor / circulation | 100 lx | ≥ 0.40 | ≤ 28 | ≥ 40 |
| Staircase | 150 lx | ≥ 0.40 | — | ≥ 40 |
| Toilet / WC | 200 lx | ≥ 0.40 | ≤ 25 | ≥ 80 |
| Warehouse (general) | 200 lx | ≥ 0.40 | ≤ 25 | ≥ 60 |
| Manufacturing (med. prec.) | 500 lx | ≥ 0.60 | ≤ 19 | ≥ 80 |
In Ireland, I.S. EN 12464-1 is incorporated into national workplace safety legislation through Safety, Health and Welfare at Work Regulations 2007. Health and Safety Authority (HSA) is responsible for overseeing compliance through workplace and building inspections. For commercial, industrial, and public buildings, lighting design documentation demonstrating conformity with I.S. EN 12464-1 must be submitted as part of the building permit application. Non-compliance can result in improvement notices and, in serious cases, suspension of occupancy permits.
Primary industries where I.S. EN 12464-1 compliance is most frequently required in Ireland.
Yes. In Ireland, I.S. EN 12464-1 is referenced in Safety, Health and Welfare at Work Regulations 2007 as the applicable technical standard for workplace lighting. All commercial, industrial, and public buildings must comply. Building inspectors from Health and Safety Authority (HSA) verify compliance during construction reviews and occupancy inspections. Failure to meet requirements can result in improvement notices or suspension of the building use permit.
Buildings that fail to meet I.S. EN 12464-1 illuminance requirements can receive enforcement notices from Health and Safety Authority (HSA). Persistent non-compliance may result in fines, revocation of occupancy permits, or mandatory retrofitting. Beyond regulatory consequences, inadequate lighting increases occupational health risks — including reduced productivity, eye strain, and accident risk — creating liability exposure for employers.
Momik reads your Revit model room by room, automatically applies I.S. EN 12464-1 illuminance targets for each space type, calculates the correct fixture placement, quantity, and layout, and generates a fully compliant lighting design — entirely within Revit. No manual lux calculations, no spreadsheets, no cross-referencing the norm tables. Typical projects are completed in under five minutes.