Reference lux levels, uniformity ratios, UGR limits, and colour rendering requirements per room type under SFS-EN 12464-1.
| Room / Task Type | Illuminance (Em) | Uniformity (Uo) | Glare (UGR) | Colour (Ra) |
|---|---|---|---|---|
| Open-plan office | 500 lx | ≥ 0.60 | ≤ 19 | ≥ 80 |
| Meeting / conference room | 500 lx | ≥ 0.60 | ≤ 19 | ≥ 80 |
| Reception / lobby | 300 lx | ≥ 0.40 | ≤ 22 | ≥ 80 |
| Corridor / circulation | 100 lx | ≥ 0.40 | ≤ 28 | ≥ 40 |
| Staircase | 150 lx | ≥ 0.40 | — | ≥ 40 |
| Toilet / WC | 200 lx | ≥ 0.40 | ≤ 25 | ≥ 80 |
| Warehouse (general) | 200 lx | ≥ 0.40 | ≤ 25 | ≥ 60 |
| Manufacturing (med. prec.) | 500 lx | ≥ 0.60 | ≤ 19 | ≥ 80 |
In Finland, SFS-EN 12464-1 is incorporated into national workplace safety legislation through Työturvallisuuslaki 738/2002. Aluehallintovirasto (Regional State Admin.) is responsible for overseeing compliance through workplace and building inspections. For commercial, industrial, and public buildings, lighting design documentation demonstrating conformity with SFS-EN 12464-1 must be submitted as part of the building permit application. Non-compliance can result in improvement notices and, in serious cases, suspension of occupancy permits.
Primary industries where SFS-EN 12464-1 compliance is most frequently required in Finland.
Yes. In Finland, SFS-EN 12464-1 is referenced in Työturvallisuuslaki 738/2002 as the applicable technical standard for workplace lighting. All commercial, industrial, and public buildings must comply. Building inspectors from Aluehallintovirasto (Regional State Admin.) verify compliance during construction reviews and occupancy inspections. Failure to meet requirements can result in improvement notices or suspension of the building use permit.
Buildings that fail to meet SFS-EN 12464-1 illuminance requirements can receive enforcement notices from Aluehallintovirasto (Regional State Admin.). Persistent non-compliance may result in fines, revocation of occupancy permits, or mandatory retrofitting. Beyond regulatory consequences, inadequate lighting increases occupational health risks — including reduced productivity, eye strain, and accident risk — creating liability exposure for employers.
Momik reads your Revit model room by room, automatically applies SFS-EN 12464-1 illuminance targets for each space type, calculates the correct fixture placement, quantity, and layout, and generates a fully compliant lighting design — entirely within Revit. No manual lux calculations, no spreadsheets, no cross-referencing the norm tables. Typical projects are completed in under five minutes.