Momik automates lighting design in Revit. Fully GB 50034 compliant. Weeks of work in minutes.
What takes weeks manually, Momik does in minutes. Fully automated lighting layout in Revit.
Every design meets GB 50034 requirements automatically. No manual norm-checking needed.
Works directly inside Autodesk Revit. No exports, no external tools, no workflow disruption.
AI-powered clash detection ensures every fixture placement is structurally valid from the start.
Reference lux levels, uniformity ratios, UGR limits, and colour rendering requirements per room type under GB 50034.
| Room / Task Type | Illuminance (Em) | Uniformity (Uo) | Glare (UGR) | Colour (Ra) |
|---|---|---|---|---|
| General office | 300 lx | ≥ 0.60 | ≤ 19 | ≥ 80 |
| Design / drafting office | 500 lx | ≥ 0.60 | ≤ 19 | ≥ 90 |
| Meeting / conference room | 300 lx | ≥ 0.60 | ≤ 19 | ≥ 80 |
| Reception / lobby | 200 lx | ≥ 0.40 | ≤ 22 | ≥ 80 |
| Corridor / circulation | 100 lx | ≥ 0.40 | — | ≥ 60 |
| Toilet / WC | 150 lx | ≥ 0.40 | ≤ 25 | ≥ 80 |
| Warehouse (general) | 100 lx | ≥ 0.40 | — | ≥ 60 |
| Manufacturing (med. prec.) | 300 lx | ≥ 0.60 | ≤ 22 | ≥ 80 |
In China, GB 50034 sets the national standard for workplace and building illumination. MOHURD (Ministry of Housing and Urban-Rural Development) oversees technical compliance under GB 50034-2013 建筑照明设计标准. Building permit applications for commercial and industrial projects require lighting design calculations. Periodic workplace inspections verify ongoing compliance with minimum illuminance requirements.
Primary industries where GB 50034 compliance is most frequently required in China.
Yes. In China, GB 50034 is adopted as the national standard for workplace illumination. MOHURD (Ministry of Housing and Urban-Rural Development) oversees compliance under GB 50034-2013 建筑照明设计标准. Building permits for commercial and industrial developments require lighting calculations demonstrating conformity. Workplace safety inspections include verification of minimum illuminance levels.
Buildings that fail to meet GB 50034 requirements can receive improvement notices from MOHURD (Ministry of Housing and Urban-Rural Development). In severe cases, occupancy permits may be revoked until lighting is retrofitted to meet minimum levels. Employers also face occupational health liability if inadequate lighting contributes to worker injuries or health issues.
Momik reads your Revit model room by room, automatically applies GB 50034 illuminance targets for each space type, calculates the correct fixture placement, quantity, and layout, and generates a fully compliant lighting design — entirely within Revit. No manual lux calculations, no spreadsheets, no cross-referencing the norm tables. Typical projects are completed in under five minutes.